Filter Results By:

Products

Applications

Manufacturers

Showing results: 1621 - 1635 of 2704 items found.

  • PCI-6519, 32-Channel, ±30 V, 16 Sink/Source Inputs, 16 Sink Outputs, Bank-Isolated Digital I/O Device

    779085-01 - NI

    The PCI-6519 is an industrial digital I/O interface, with two banks optically isolated channels. The device is ideal for industrial control and manufacturing test applications. The PCI-6519 module is an industrial digital I/O interface, with eight banks of isolated channels. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6519 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions.

  • Spectrum Analysis, Up To 70 GHz

    S930907B - Keysight Technologies

    The S930907B spectrum analysis (SA) adds high-performance microwave spectrum analysis to the N522xB/N524xB PNA family up to 70 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Spectrum Analysis, Up To 26.5 GHz

    S930902B - Keysight Technologies

    The S930902B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 26.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • PXI-5650, 1.3 GHz RF Signal Generator

    779670-00 - NI

    The PXI‑5650 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXI‑5650 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • Spectrum Analysis, Up To 13.5 GHz

    S930901B - Keysight Technologies

    The S930901B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 13.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • PXIe-5650, 1.3 GHz RF Signal Generator

    781215-01 - NI

    The PXIe‑5650 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXIe‑5650 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • NI LabVIEW Base Development System for Windows

    NI

    NLabVIEW is system engineering software designed for applications that require test, measurement, and control with rapid access to hardware and data insights. The LabVIEW Base Development System is recommended to integrate NI hardware and third-party devices together to build automated desktop measurement applications with an intuitive graphical programming syntax.For applications that require advanced inline analysis or PID control, consider LabVIEW Full Development System.

  • Reverberation Chambers

    EMCTEST

    Over the past several decades, RCs have been enjoying growing popularity as a promising facility for the characterization of wireless devices and for EMC testing. The RC (Reverberation Chamber) measurement method exhibits much competitive superiority over the AC (Anechoic Chamber) method and TEM Cell method, such as low cost, enhanced test repeatability, a more realistic test environment, and easily achieved high-field environment. The application of the RC for performing EMC testing was first proposed by H. A. Mendes in 1968. In the recent IEC 61000-4-21 standard, the importance of EMC testing using RCs as an alternative measurement technique has been recognized.

  • Avionics Interfaces & Test Instruments

    ARINC 664 - Avionics Interface Technologies

    AIT’s ARINC 664 test instruments can be used in test and simulation applications that are required to transmit and receive data over the ARINC 664 avionics databus. AIT’s instruments use small form-factor pluggable transceivers (SFP) and support copper or fiber optic physical network interfaces.Using an FPGA based architecture, with multiple embedded processors, the ARINC 664 instruments provide onboard support for upper layer protocol processing (A653, UDP, IP) and utilize DMA to provide optimal data throughput. All ARINC 664 protocol operations, including VL traffic shaping, redundancy management, and IP fragmentation and reassembly, are handled onboard.

  • Decade Box, Calibrated W/Data, Capacitance, 5, 100pF to 11111µF, 5 %

    72-7265 CAL D - Tenma

    The 72-7265 CAL D from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.

  • Decade Box, Calibrated, Capacitance, 5, 100pF to 11111µF, 5 %

    72-7265 CAL - Tenma

    The 72-7265 CAL from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.

  • Decade Box, Calibrated W/D & U, Capacitance, 5, 100pF to 11111µF, 5 %

    72-7265 CAL DU - Tenma

    The 72-7265 CAL DU from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.

  • Package Test Loadboards/DIB

    Dynamic Test Solutions

    DTS Package Test (DIB) loadboards are designed to specific devices and configured for both hand test and fully automated handler applications. DTS loadboards incorporate any brand of socket or contactor and can be configured for multi-site testing. Designs incorporate all necessary components, connectors, mechanical hardware and stiffeners to provide a complete plug-n-play solution. DTS has a vast database of tester and handler information which allow designs to be started and completed quickly without burdening the customer to supply excessive information. DTS designers are experienced in all device types, including digital, analog, mixed signal and RF devices.

  • Tensile Test Methods For Plastics: ISO 527 And JIS K 7161

    Shimadzu Corp.

    Resin materials (plastics) are found in a wide variety of items used on a daily basis. Recently, plastics have started to be used as structural materials in transportation equipment, such as automobiles and aircraft, due to their strength and light-weight nature. In these applications, it is important to understand the mechanical strength properties of these plastics. ISO 527 and JIS K 7161 outline methods for testing the tensile strength of plastics and other resin materials. Included in these methods are accuracy specifications for the test frame and test accessories. The contents of ISO 527 and JIS K 7161 are basically the same, but differ from the equivalent ASTM standard for tensile testing of plastics, ASTM D638.

  • PXIe-2527, 32‐Channel, 300 V, 2‐Wire PXI Multiplexer Switch Module

    780587-27 - NI

    32‐Channel, 300 V, 2‐Wire PXI Multiplexer Switch Module—The PXIe‑2527 is a high‐voltage PXI multiplexer switch module that is ideal for medium‑ to high‑density automated test applications. Featuring high-power electromechanical relays, the PXIe‑2527 is the perfect front end for the PXI DMM modules, offering simple channel expansion for a variety of measurements. The PXIe‑2527 supports multiple channel configurations including 64x1 1‑wire, 32x1 2‑wire, and 16x1 4‑wire. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.

Get Help